Hydraulic Axial Piston A2fe63 80 45 56 Motor Rexroth Brand

Hydraulic Axial Piston A2fe63 80 45  56 Motor Rexroth Brand

 CZPT axial piston A2fe63/eighty/45 /fifty six Motor  CZPT Brand 

Brueninghaus Hydromatik CZPT A2FE motor
 
CZPT fastened motor A2FE28, A2FE32, A2FE45, A2FE56, A2FE63, A2FE80, A2FE90, A2FE107, A2FE125, A2FE160, A2FE180,
A2FE250, A2FE355

Description  

Open and closed circuits
Collection 61 and sixty
Strain:
Size 28 to180 Nominal stress 5800 psi (four hundred bar)/ Peak pressure 6500 psi (450 bar)
Dimension 250 to 355 Nominal strain 5100 psi (350 bar)/ Peak stress 5800 psi (four hundred bar)
 
The A2FE mounted plug-in motor with axial tapered piston rotary team of bent-axis design, for hydrostatic drives in open up and shut circuits
-Far-achieving integration in mechanical gearbox owing to recessed mounting flange found in the center of the situation (really place-preserving construction)
-The output pace is dependent on the stream of the pump and the displacement of the motor.
-The output torque raises with the pressure differential among the substantial-force and the lower-force aspect.
-Small dimensions.
-High overall performance.
-CZPT device, all set-assembled and examined.
-Straightforward to set up, simply plug into the mechanical gearbox.
-No configuration requirements to be observed when setting up.
 
CZPT Data 
Desk of values (theoretical values, with out effectiveness and tolerances values rounded)

CZPT A2FE motor A2FE28 A2FE32 A2FE45 A2FE56 A2FE63 A2FE80  
Displacement Vg cm3 28.one 32 forty five.six 56.1 sixty three eighty.4  
Velocity optimum nnom rpm 6300 6300 5600 5000 5000 4500  
nmax2) rpm 6900 6900 6200 5500 5500 5000  
Input flow Vg qV L/min 177 202 255 281 315 362  
Torque at Vg and Dp = 350 bar T Nm 157 178 254 313 351  
Dp = 400 bar T Nm 179 204 290 357 401  
Rotary stiffness c kNm/ rad 2.93 three.12 4.eighteen five.ninety four six.25 eight.seventy three  
Moment of inertia JGR  kgm2 .0012 .0012 .0571 .0042 .0042 .0072  
Maximum angular a rad/s2 6500 6500 14600 7500 7500 6000  
Circumstance quantity V  L .2 .2 .33 .forty five .45 .55  
Mass (approx.) m kg 10.5 ten.5 15 18 19 23  
Measurement A2FE90 A2FE107 A2FE125 A2FE160 A2FE180 A2FE250 A2FE355
Displacement Vg cm3 ninety 106.7 125 one hundred sixty.4 one hundred eighty 250 355
Pace optimum nnom rpm 4500 4000 4000 3600 3600 2700 2240
nmax2) rpm 5000 4400 4400 4000 4000
Input movement qV L/min 405 427 five hundred 577 648 675 795
Torque at Vg Dp = 350 bar T 501 594 696 893 1003 1393 1978
Dp = 400 bar T 573 679 796 1571 1146
Rotary stiffness c kNm/rad nine.fourteen 11.2 eleven.9 17.four eighteen.two 73.one 96.one
Moment of inertia JGR kgm2 .0072 .0116 .0116 .571 .571 .061 .102
Greatest angular a rad/s2 6000 4500 4500 3500 3500 ten thousand 8300
Circumstance quantity V L .fifty five .8 .8 1.1 1.1 2.5 3.5
Mass (approx.) m kg twenty five 34 36 47 forty eight eighty two one hundred ten

CZPT fluid
Just before starting venture plHangZhou, remember to refer to our data sheets RE 95710 (mineral oil), RE 95711 (environmentally suitable hydraulic fluids) and RE 95712 (HFD hydraulic fluids) and RE 95713 (HFA, HFB, HFC hydraulic fluids) for detailed information with regards to the decision of hydraulic fluid and software situations. The plug-in motor A2FE is not appropriate for procedure with HFA hydraulic fluid. If HFB, HFC or HFD or environmentally suitable hydraulic fluids are utilized, the limitations regarding specialized knowledge or other seals must be observed.
Information concerning the selection of hydraulic fluid
The appropriate choice of hydraulic fluid needs knowledge of the functioning temperature in relation to the ambient temperature: in a closed circuit, the circuit temperature, in an open up circuit, the reservoir temperature. The hydraulic fluid need to be chosen so that the running viscosity in the running temperature selection is within the optimum selection (νopt), see shaded spot of the choice diagram. We recommended that the greater viscosity course be selected in each case. Case in point: At an ambient temperature of X °C, an working temperature of 60 °C is set in the circuit. In the optimum working viscosity assortment (νopt., shaded region) this corresponds to the viscosity classes VG forty six or VG sixty eight to be selected: VG sixty eight.
Observe: The situation drain temperature, which is afflicted by strain and pace, can be greater than the circuit temperature or reservoir temperature. At no stage of the component could the temperature be increased than one hundred fifteen °C. The temperature difference specified under is to be taken into account when figuring out the viscosity in the bearing. If the previously mentioned circumstances are not able to be taken care of thanks to excessive working parameters, we recommend the use of a flushing and improve pressure valve.
Shaft seal
Permissible stress loading the service life of the shaft seal is affected by the pace of the axial piston unit and the circumstance drain strain (situation pressure). The mean differential pressure of 2 bar in between the situation and the ambient force might not be enduringly exceeded at typical running temperature. For a higher differential force at reduced speed, see diagram. Momentary stress spikes (t < 0.1 s) of up to 10 bar are permitted. The service life of the shaft seal decreases with an increase in the frequency of pressure spikes.

 

Hydraulic Axial Piston A2fe63 80 45  56 Motor Rexroth Brand